Home Analyst, Inc.
P.O. Box 670774 |
|||||||
Customer |
|||||||
Home |
|||||||
Real Estate Agent |
|||||||
|
|||||||
|
|||||||
| Date: 2/6/2006 | Time: 9:40 AM | Report ID: 06020601-Presale Example After Improvements |
| Property: 3409 New Home Drive Sandy Springs, GA 30355 |
Customer: Recycled Homes, Inc. |
Real Estate Professional: FSBO |
It is a pleasure serving you,
| Client Is Present: Yes | Age Of Home: 1955 | Radon Test: No |
| Water Test: No | Weather: Light Rain | Temperature: 34 |
| Rain in last 3 days: Yes |
GAHI Limitations for Structural Components
The Inspector is not required to:
| FOUNDATION: ROCK | METHOD USED TO OBSERVE CRAWLSPACE: CRAWLED | FLOOR STRUCTURE: 2 X 10 |
| WALL STRUCTURE: 2 X 4 WOOD | COLUMNS OR PIERS: MASONRY BLOCK STEEL SCREW JACKS SUPPORTING WALLS | CEILING STRUCTURE: 2X8 |
| ROOF STRUCTURE: STICK-BUILT 2 X 6 RAFTERS COMMON BOARD | ROOF-TYPE: GABLE HIP | ATTIC ACCESS TYPES PRESENT: DROP-DOWN STAIRS |
| ATTIC ACCESS LOCATIONS: HALLWAY |
| IN | NI | NP | C | RR | ||
| 1.0 | FOUNDATIONS (Structural) | X | X | |||
| 1.1 | FLOORS (Structural) | X | X | |||
| 1.2 | WALLS (Structural) | X | ||||
| 1.3 | COLUMNS OR PIERS | X | ||||
| 1.4 | CEILINGS (Structural) | X | ||||
| 1.5 | ATTIC AND ROOF STRUCTURE | X | X | |||
| 1.6 | CRAWLSPACE | X | X | |||
| 1.7 | CRAWLSPACE ENTRY LOCATION | X | ||||
| IN | NI | NP | C | RR | ||
Note: pictures 6 - 8 are after improvement photos.
![]() 1.1 Picture 1 |
![]() 1.1 Picture 2 | ![]() 1.1 Picture 3 |
![]() 1.1 Picture 4 | ![]() 1.1 Picture 5 |
![]() 1.1 Picture 6 |
![]() 1.1 Picture 7 |
![]() 1.1 Picture 8 |
![]() 1.5 Picture 1 |
![]() 1.5 Picture 2 |
Note: picture 4 is an after improvement photo.
![]() 1.6 Picture 1 | ![]() 1.6 Picture 2 |
![]() 1.6 Picture 3 |
![]() 1.6 Picture 4 |
GAHI Limitations for Grounds and Appurtenances
The Inspector is not required to:
GAHI Limitations for Building Exterior
The Inspector is not required to:
| DRIVEWAY: CONCRETE | EXTERIOR ENTRY DOORS: WOOD | SIDING STYLE: BRICK |
| PORCH (S): CONCRETE | SIDING MATERIAL: BRICK VENEER | STAIRS EXTERIOR: CONCRETE |
| WINDOW TYPES: AGED DOUBLE-HUNG SINGLE PANE SLIDERS WOOD | WINDOW MANUFACTURER: UNKNOWN | WALKWAYS: CONCRETE |
| IN | NI | NP | C | RR | ||
| 2.0 | WALL CLADDING, FLASHING AND TRIM | X | X | |||
| 2.1 | DOORS (Exterior) | X | X | |||
| 2.2 | WINDOWS | X | ||||
| 2.3 | STORM DOORS AND WINDOWS | X | ||||
| 2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | X | ||||
| 2.5 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building and it's systems) | X | X | |||
| 2.6 | EAVES, SOFFITS AND FASCIAS | X | X | |||
| 2.7 | GROUND COVER& VEGETATION (condition) | X | X | |||
| IN | NI | NP | C | RR | ||
Note: picture 2 is an after improvement photo.
![]() 2.0 Picture 1 |
![]() 2.0 Picture 2 |
![]() 2.0 Picture 3 |
![]() 2.0 Picture 4 | ![]() 2.0 Picture 5 |
![]() 2.0 Picture 6 |
![]() 2.0 Picture 7 |
![]() 2.1 Picture 1 | ![]() 2.1 Picture 2 |
![]() 2.5 Picture 1 | ![]() 2.5 Picture 2 |
![]() 2.5 Picture 3 | ![]() 2.5 Picture 4 |
Note: picture 2 is an after improvement photo.
![]() 2.6 Picture 1 |
![]() 2.6 Picture 2 |
GAHI Limitations for Roof, Guttering and Other Roof Components
The Inspector is not required to:
| CHIMNEY (exterior): N/A | VIEWED ROOF COVERING FROM: GROUND | ROOF COVERING: 3-TAB FIBERGLASS |
| ROOF STYLE: HIP GABLE | ROOF PITCH: MEDIUM | SKY LIGHT (S): NONE |
| FLASHING: NOT PRESENT |
| IN | NI | NP | C | RR | ||
| 3.0 | ROOF COVERINGS | X | X | |||
| 3.1 | FLASHINGS | X | ||||
| 3.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS | X | X | |||
| 3.3 | ROOFING DRAINAGE SYSTEMS, GUTTERS& DOWNSPOUTS | X | ||||
| 3.4 | AREAS OF ROOF NOT VISIBLE | X | ||||
| IN | NI | NP | C | RR | ||
High level of moisture indicating active leaking from this location into the interior walls was found on the ceiling and above the front windows (see photos). Ma
Recommend having a qualified roofer make the appropriate repairs.
For location(s) see photo(s):
Note: pictures 7 - 9 are after improvement photos.
![]() 3.0 Picture 1 | ![]() 3.0 Picture 2 |
![]() 3.0 Picture 3 | ![]() 3.0 Picture 4 |
![]() 3.0 Picture 5 | ![]() 3.0 Picture 6 |
![]() 3.0 Picture 7 |
![]() 3.0 Picture 8 |
![]() 3.0 Picture 9 |
For details and/or examples see photo(s):
Note: pictures 2 - 3 are after improvement photos.
![]() 3.2 Picture 1 |
![]() 3.2 Picture 2 |
![]() 3.2 Picture 3 |
![]() 3.2 Picture 4 | ![]() 3.2 Picture 5 |
GAHI Limitations for Plumbing
The Inspector is not required to:
| WATER SOURCE: PUBLIC | WATER FILTERS: NONE | PLUMBING SUPPLY: COPPER |
| PLUMBING DISTRIBUTION: COPPER | WASHER DRAIN SIZE: 2" DIAMETER | PLUMBING WASTE: CAST IRON (OLD) |
| WATER HEATER POWER SOURCE: GAS (QUICK RECOVERY) | CAPACITY: 40 GAL (1-2 PEOPLE) | MANUFACTURER: RHEEM |
| AGE OF WATER HEATER: 2000 |
| IN | NI | NP | C | RR | ||
| 4.0 | INTERIOR WATER PRESSURE (record pressure) | X | ||||
| 4.1 | INTERIOR WATER SUPPLY, DISTRIBUTION SYSTEMS AND FIXTURES | X | ||||
| 4.2 | SHOWER / TUB SURROUNDS AND ENCLOSURES | X | X | |||
| 4.3 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES, VENTS, AND RELIEF SYSTEMS | X | ||||
| 4.4 | INTERIOR DRAIN, WASTE AND VENT SYSTEMS | X | X | |||
| 4.5 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) | X | ||||
| 4.6 | SUMP PUMP | X | X | |||
| 4.7 | LOCATION OF WASHER / DRYER CONNECTIONS | X | ||||
| 4.8 | LOCATION OF MAIN FUEL SHUT OFF VALVE | X | ||||
| 4.9 | MAIN WATER SHUT-OFF DEVICE (Describe location) | X | ||||
| IN | NI | NP | C | RR | ||
Code IPC GA Amended 607.3.2 Backflow prevention Device or check valve. Where a backflow prevention device, check valve or other device is installed on a water supply system utilizing storage water heating equipment such that thermal expansion causes an increase in pressure, a device for controlling pressure shall be installed. The device shall limit thermal expansion of the water being heated to not more than 80 pounds per square inch static pressure at any fixture on the system. A potable water expansion tank, or auxiliary relief valve or other approved device that limits pressure to 80 psi or less shall be acceptable. It shall be installed in accordance with manufacturer's instructions. (Effective January 1, 2001).
![]() 4.4 Picture 1 |
![]() 4.6 Picture 1 |
![]() 4.8 Picture 1 |
![]() 4.9 Picture 1 |
GAHI Limitations for Electrical
The Inspector is not required to:
| ELECTRICAL CONDUCTORS: ABOVE GROUND ALUMINUM 220 VOLTS | PANEL CAPACITY: 150 AMP | PANEL TYPE: CIRCUITS |
| ELEC. PANEL MANUFACTURER: GOULD | BRANCH WIRE 15 and 20 AMP: COPPER | WIRING METHODS: ROMEX |
| IN | NI | NP | C | RR | ||
| 5.0 | SERVICE ENTRANCE CONDUCTORS | X | ||||
| 5.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS | X | X | |||
| 5.2 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE | X | X | |||
| 5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | X | X | |||
| 5.4 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE | X | ||||
| 5.5 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) | X | ||||
| 5.6 | SMOKE DETECTORS | X | ||||
| 5.7 | LOCATION OF MAIN AND DISTRIBUTION PANELS | X | ||||
| IN | NI | NP | C | RR | ||
For details and/or examples see photo(s):
![]() 5.1 Picture 1 |
For details and/or examples see photo(s):
![]() 5.2 Picture 1 | ![]() 5.2 Picture 2 |
![]() 5.2 Picture 3 |
For details and/or examples see photo(s):
Note: pictures 5 is an after improvement photo.
![]() 5.3 Picture 1 | ![]() 5.3 Picture 2 |
![]() 5.3 Picture 3 | ![]() 5.3 Picture 4 |
![]() 5.3 Picture 5 |
![]() 5.7 Picture 1 |
GAHI Limitations for Heating and Cooling Equipment and Systems
The Inspector is not required to:
| HEAT TYPE: FORCED AIR | ENERGY SOURCE: GAS | NUMBER OF HEAT SYSTEMS (excluding wood): ONE |
| HEAT SYSTEM BRAND: GOODMAN | DUCTWORK: INSULATED And NON-INSULATED POSSIBLE ASBESTOS TAPE AROUND CONNECTIONS | FILTER TYPE: DISPOSABLE |
| FILTER SIZE: 20x20 | TYPES OF FIREPLACES: NONE | OPERABLE FIREPLACES: NONE |
| NUMBER OF WOODSTOVES: NONE | FURNACE BTU/HR.: 75000 | APPROXIMATE AGE: 2003 |
| IN | NI | NP | C | RR | ||
| 6.0 | HEATING EQUIPMENT | X | X | |||
| 6.1 | HEATING EQUIPMENT LOCATION | X | ||||
| 6.2 | NORMAL OPERATING CONTROLS | X | ||||
| 6.3 | AUTOMATIC SAFETY CONTROLS | X | ||||
| 6.4 | CHIMNEYS, FLUES AND VENTS | X | X | |||
| 6.5 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | X | X | |||
| IN | NI | NP | C | RR | ||
![]() 6.0 Picture 1 |
![]() 6.4 Picture 1 |
Note: pictures 7 - 8 are after improvement photos.
![]() 6.5 Picture 1 | ![]() 6.5 Picture 2 |
![]() 6.5 Picture 3 | ![]() 6.5 Picture 4 |
![]() 6.5 Picture 5 | ![]() 6.5 Picture 6 |
![]() 6.5 Picture 7 |
![]() 6.5 Picture 8 |
| NUMBER OF A/C UNITS: ONE | COOLING EQUIPMENT TYPE: AIR CONDITIONER UNIT | COOLING EQUIPMENT ENERGY SOURCE: ELECTRICITY |
| CENTRAL AIR MANUFACTURER: GOODMAN | COOLING EQUIPMENT CAPACITY IN TONS: 3.0 | AGE OF COMPRESSOR (S): 2000 |
| IN | NI | NP | C | RR | ||
| 7.0 | COOLING EQUIPMENT LOCATION | X | ||||
| 7.1 | COOLING AND AIR HANDLER EQUIPMENT | X | ||||
| 7.2 | NORMAL OPERATING CONTROLS | X | ||||
| 7.3 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | X | ||||
| IN | NI | NP | C | RR | ||
The AC should be tested when the outside temperature has been above 65 degrees for 24 hours. Ensure that there is a 14 to 20 degree temperature drop. This temperature drop is measured by comparing supply duct and return air duct temperatures. Have a qualified HVAC technician inspect the system, add cooling fluid if necessary and ensure that the temperature drop is appropriate.
GAHI Limitations for General Interior
The Inspector is not required to:
| CEILING MATERIALS: SHEETROCK | WALL MATERIAL: SHEETROCK | FLOOR COVERING(S): HARDWOOD T&G LINOLEUM TILE WOOD |
| INTERIOR DOORS: HOLLOW CORE | CABINETRY: WOOD | COUNTERTOP: LAMINATE |
| IN | NI | NP | C | RR | ||
| 8.0 | CEILINGS | X | ||||
| 8.1 | WALLS | X | X | |||
| 8.2 | FLOORS | X | X | |||
| 8.3 | DOORS (REPRESENTATIVE NUMBER) | X | X | |||
| 8.4 | WINDOWS (REPRESENTATIVE NUMBER) | X | X | |||
| 8.5 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS | X | ||||
| 8.6 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS AND DRAWERS | X | ||||
| IN | NI | NP | C | RR | ||
Note: picture 2 is an after improvement photo.
![]() 8.1 Picture 1 | ![]() 8.1 Picture 2 |
![]() 8.1 Picture 3 |
Note: picture 2 is an after improvement photo.
![]() 8.2 Picture 1 |
![]() 8.2 Picture 2 |
![]() 8.3 Picture 1 | ![]() 8.3 Picture 2 |
![]() 8.4 Picture 1 |
![]() 8.4 Picture 2 |
![]() 8.4 Picture 3 | ![]() 8.4 Picture 4 |
GAHI Limitations for Insulation and Ventilation
The Inspector is not required to:
| R- VALUE: BELOW R-19 | ATTIC INSULATION: BLOWN CELLULOSE | EXHAUST FAN TYPES: FAN ONLY |
| DRYER POWER SOURCE: 22O ELECTRIC GAS CONNECTION | DRYER VENT: METAL | ATTIC VENTILATION: GABLE VENTS SOFFIT VENTS Thermostatically controlled fan |
| IN | NI | NP | C | RR | ||
| 9.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces) | X | ||||
| 9.1 | VENTILATION OF ATTIC AND FOUNDATION AREAS | X | X | |||
| 9.2 | VENTING SYSTEMS (Kitchens, baths and laundry) | X | X | |||
| 9.3 | VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC) | X | X | |||
| IN | NI | NP | C | RR | ||
![]() 9.1 Picture 1 |
![]() 9.2 Picture 1 |
![]() 9.2 Picture 2 |
![]() 9.3 Picture 1 |
GAHI Limitations for Kitchen and Appliances
The Inspector is not required to:
| DISHWASHER: MAGIC CHEF | DISPOSER: NONE | EXHAUST/RANGE HOOD: NUTONE |
| RANGE/OVEN: HOTPOINT | BUILT-IN MICROWAVE: NONE | TRASH COMPACTORS: NONE |
| REFRIGERATOR: MAGIC CHEF |
| IN | NI | NP | C | RR | ||
| 10.0 | DISHWASHER | X | ||||
| 10.1 | RANGES/OVENS/COOKTOPS | X | ||||
| 10.2 | RANGE HOOD | X | ||||
| 10.3 | TRASH COMPACTOR | X | ||||
| 10.4 | FOOD WASTE DISPOSER | X | ||||
| 10.5 | BUILT IN MICROWAVE COOKING EQUIPMENT | X | ||||
| 10.6 | REFRIGERATOR | X | ||||
| IN | NI | NP | C | RR | ||
| IN | NI | NP | C | RR | ||
| 11.0 | ATTIC VIEW | X | ||||
| 11.1 | DEN VIEW | X | ||||
| 11.2 | HALL BATH VIEW | X | ||||
| 11.3 | LIVING ROOM VIEW | X | ||||
| 11.4 | MASTER BEDROOM VIEW | X | ||||
| 11.5 | MASTER BATH VIEW | X | ||||
| 11.6 | SUNROOM | X | ||||
| IN | NI | NP | C | RR | ||
![]() 11.0 Picture 1 |
![]() 11.1 Picture 1 |
![]() 11.2 Picture 1 |
![]() 11.3 Picture 1 |
![]() 11.4 Picture 1 |
![]() 11.5 Picture 1 |
![]() 11.6 Picture 1 |
![]() Home Analyst, Inc.
P.O. Box 670774 |
Customer |
Property Address |
| 1.0 | FOUNDATIONS (Structural) | |
| Inspected, Repair or Replace | ||
|
Crack in wall at rear of home. The
appearance of settlement crack is not large enough for concern.
Recommend filling void area to prevent additional cracking. |
||
| 1.1 | FLOORS (Structural) | |
| Inspected, Repair or Replace | ||
|
Bathroom floor has dropped due to damage
to girder below in crawlspace. Make repairs as necessary to the
girder. Ensure that the floor to tub joint is well sealed to
prevent water penetration to the framing below. See photos for
details Note: pictures 6 - 8 are after improvement photos. |
||
| 1.5 | ATTIC AND ROOF STRUCTURE | |
| Inspected, Repair or Replace | ||
|
Pull down stairs is too long. This
places too much pressure on the joint. To improve safety and
stability of the ladder shorten attic stairs so that the sides of the
ladder make a straight line.. |
||
| 1.6 | CRAWLSPACE | |
| Inspected, Repair or Replace | ||
|
Remove building debris from crawlspace. See photos for examples.
Note: picture 4 is an after improvement photo. |
||
| 2.0 | WALL CLADDING, FLASHING AND TRIM | |
| Inspected, Repair or Replace | ||
|
Stone veneer at left front corner has
come loose. This stone (see photo 1) supported a brick lentil and
brick veneer. Brick veneer has cracked. The damage does not
involve the foundation. Have a qualified contractor or mason make
the appropriate repairs. Note: picture 2 is an after improvement photo. |
||
| 2.5 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building and it's systems) | |
| Inspected, Repair or Replace | ||
|
Negative slope towards right side (facing
front)and left front corner near downspout. These areas do not appear
to drain water away from home and needs landscaping and drainage
corrected. See photos with water draining into the crawlspace. |
||
|
Vegetation is in contact with the
house. Keep all vegetation trimmed away from siding and roof to
reduce the possibility of water and insect damage. |
||
| 2.6 | EAVES, SOFFITS AND FASCIAS | |
| Inspected, Repair or Replace | ||
|
Roof leak has caused water damage to the
soffit at the left, front and right of the porch, water is also
entering into the wall cavity and onto the living room ceiling.
See the roofing section for more discussion. Recommend having a
qualified contractor or roofer make the appropriate repairs
Note: picture 2 is an after improvement photo. |
||
| 2.7 | GROUND COVER& VEGETATION (condition) | |
| Inspected, Repair or Replace | ||
|
Condition of vegetation is average. |
||
| 3.0 | ROOF COVERINGS | |
| Inspected, Repair or Replace | ||
|
Repair damaged shingles at rear roof
corners, left side roof just above eve the gutter and at front valley
over the front porch. High level of moisture indicating active leaking from this location into the interior walls was found on the ceiling and above the front windows (see photos). Ma Recommend having a qualified roofer make the appropriate repairs. For location(s) see photo(s): Note: pictures 7 - 9 are after improvement photos. |
||
| 3.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS | |
| Inspected, Repair or Replace | ||
|
Flue or vent boot flashing has lifted and needs to be reset to the roof and sealed.
For details and/or examples see photo(s): Note: pictures 2 - 3 are after improvement photos. |
||
|
Roof leak in the area of the electrical
mast. Water seen dripping at trim board below. For details
and/or examples see photo(s): |
||
| 4.1 | INTERIOR WATER SUPPLY, DISTRIBUTION SYSTEMS AND FIXTURES | |
| Not Inspected | ||
|
Water was shut off at time of the inspection. |
||
| 4.2 | SHOWER / TUB SURROUNDS AND ENCLOSURES | |
| Inspected, Repair or Replace | ||
|
Seal the tub and tile floor joint
with a high quality sealant to prevent water intrusion and subsequent
damage to flooring material and structural components. |
||
| 4.4 | INTERIOR DRAIN, WASTE AND VENT SYSTEMS | |
| Not Inspected, Repair or Replace | ||
|
Unable to test system for leaks. Water was shut off at time of inspection. |
||
|
Toilet is loose at floor . Repair may involve resetting the toilet on a new wax seal at Master Bath. |
||
|
PVC line with damaged cover. Clean out the pipe, determine use and properly cover. |
||
| 4.6 | SUMP PUMP | |
| Inspected, Repair or Replace | ||
|
Visible signs of water intrusion in
crawlspace are present and a"Sump Pump" is installed. Existing sump
pump makes loud noise at times when tested. A bearing may be
failing requiring repair or replacement of the pump and or motor.
Unable to determine the extent of intrusion or how often it
occurs. Sump was dry at time of inspection. |
||
| 5.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS | |
| Inspected, Repair or Replace | ||
1.0 Picture 1
Vertical crack in foundation wall front. This crack does not appear significant to require repairs at this time.
1.0 Picture 2
Visible signs of water intrusion in crawlspace are present from standing water. Unable to determine the extent of intrusion or how often it occurs. Located at left front corner. See grading in exterior section where grade slopes towards house and traps downspout discharge.
1.0 Picture 3