Inspection Date: 
2/6/2006
 
Weather:
Light Rain
Report ID:
06020601-Presale Example After Improvements
Temperature:
34
Inspected By:
Bruce Rickey



Date: 2/6/2006 Time: 9:40 AM Report ID: 06020601-Presale Example After Improvements
Property:
3409 New Home Drive
Sandy Springs, GA 30355
Customer:
Recycled Homes, Inc.
Real Estate Professional:
FSBO

This inspection was performed for the home owner selling this home and was inspected according to standards and practices. The comments made in this report was based on the condition of the home at time of inspection. There is no warranty from the inspection company. For a fee, our company can return and review the inspection, or inspect the home again. The proposed buyer can hire a different inspector if desired. Different inspectors can find different things sometimes on the same home. My inspection company is not responsible for any discoveries included or not found. As this inspection report ages, the condition of this home and its components can change. 

 

It is a pleasure serving you,

Client Is Present:
Yes

Age Of Home:
1955

Radon Test:
No

Water Test:
No

Weather:
Light Rain

Temperature:
34

Rain in last 3 days:
Yes




STRUCTURAL COMPONENTS

GAHI Limitations for Structural Components

The Inspector is not required to:

  1. Enter crawl spaces with headroom less than two feet or where adverse conditions exist.
  2. Move stored items or debris.
  3. Enter areas that may contain hazardous materials.
  4. Determine the extent of damage by insects or water.
  5. Operate sump pumps or drainage systems.
  6. Enter attic spaces where the headroom is less than 30 inches.
  7. Enter attic spaces wehre hazardous conditions exist.

 

Styles & Materials
FOUNDATION:
ROCK
METHOD USED TO OBSERVE CRAWLSPACE:
CRAWLED
FLOOR STRUCTURE:
2 X 10
WALL STRUCTURE:
2 X 4 WOOD
COLUMNS OR PIERS:
MASONRY BLOCK
STEEL SCREW JACKS
SUPPORTING WALLS
CEILING STRUCTURE:
2X8
ROOF STRUCTURE:
STICK-BUILT
2 X 6 RAFTERS
COMMON BOARD
ROOF-TYPE:
GABLE
HIP
ATTIC ACCESS TYPES PRESENT:
DROP-DOWN STAIRS
ATTIC ACCESS LOCATIONS:
HALLWAY

 INNINPCRR
1.0 FOUNDATIONS (Structural)X   X
1.1 FLOORS (Structural)X   X
1.2 WALLS (Structural)X    
1.3 COLUMNS OR PIERSX    
1.4 CEILINGS (Structural)X    
1.5 ATTIC AND ROOF STRUCTUREX   X
1.6 CRAWLSPACEX   X
1.7 CRAWLSPACE ENTRY LOCATIONX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
1.0 Crack in wall at rear of home. The appearance of settlement crack is not large enough for concern. Recommend filling void area to prevent additional cracking.

1.0 Picture 1

Vertical crack in foundation wall front. This crack does not appear significant to require repairs at this time.

1.0 Picture 2

Visible signs of water intrusion in crawlspace are present from standing water. Unable to determine the extent of intrusion or how often it occurs. Located at left front corner.  See grading in exterior section where grade slopes towards house and traps downspout discharge.

1.0 Picture 3
1.1 Bathroom floor has dropped due to damage to girder below in crawlspace.  Make repairs as necessary to the girder.  Ensure that the floor to tub joint is well sealed to prevent water penetration to the framing below.  See photos for details

Note: pictures 6 - 8 are after improvement photos.



1.1 Picture 1

1.1 Picture 2

1.1 Picture 3

1.1 Picture 4

1.1 Picture 5

1.1 Picture 6

1.1 Picture 7

1.1 Picture 8
1.5 Pull down stairs is too long.  This places too much pressure on the joint.  To improve safety and stability of the ladder shorten attic stairs so that the sides of the ladder make a straight line..

1.5 Picture 1

Wood slats on roof damaged (above Guest bedroom). Recommend repair or replace as needed.

1.5 Picture 2
1.6 Remove building debris from crawlspace.  See photos for examples.

Note: picture 4 is an after improvement photo.



1.6 Picture 1

1.6 Picture 2

1.6 Picture 3

1.6 Picture 4
1.7 Right side of the house.

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email atbruce@yourhomeanalyst.com.




EXTERIOR

GAHI Limitations for Grounds and Appurtenances

The Inspector is not required to:

  1. Identify or report the observed condition of fences (except if around a swimming pool), playground or other recreational equipment, fire or lawn sprinklers, swimming; spas or jetted tubs, below ground drainage or septic systems, water wells out buildings or storage buildings except detached garages.
  2. determine property line boundaries, soil, or geological conditions.

GAHI Limitations for Building Exterior

The Inspector is not required to:

  1. Report on the adaquacy of storm windows or storm doors.
  2. Report on the quality or contents of the paint.
  3. Inspect or report on decks or other structures that are not attached to the dwelling.
  4. Report on the presence of screens.
  5. Identify the method of treatment of any preservative treated lumber.
  6. Identify the type/method of corrosion resistance of any fastners or connectors and/or the suitability of use of any fasteners or connectors with any preservative treated lumber.

Styles & Materials
DRIVEWAY:
CONCRETE
EXTERIOR ENTRY DOORS:
WOOD
SIDING STYLE:
BRICK
PORCH (S):
CONCRETE
SIDING MATERIAL:
BRICK VENEER
STAIRS EXTERIOR:
CONCRETE
WINDOW TYPES:
AGED
DOUBLE-HUNG
SINGLE PANE
SLIDERS
WOOD
WINDOW MANUFACTURER:
UNKNOWN
WALKWAYS:
CONCRETE

 INNINPCRR
2.0 WALL CLADDING, FLASHING AND TRIMX   X
2.1 DOORS (Exterior)X   X
2.2 WINDOWSX    
2.3 STORM DOORS AND WINDOWS  X  
2.4 DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGSX    
2.5 VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building and it's systems)X   X
2.6 EAVES, SOFFITS AND FASCIASX   X
2.7 GROUND COVER& VEGETATION (condition)X   X
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
2.0 Stone veneer at left front corner has come loose.  This stone (see photo 1) supported a brick lentil and brick veneer.  Brick veneer has cracked.  The damage does not involve the foundation.  Have a qualified contractor or mason make the appropriate repairs.

Note: picture 2  is an after improvement photo.



2.0 Picture 1

2.0 Picture 2

Minor crack in front stone wall noted.  No further repairs needed at this time.

2.0 Picture 3

Minor crack in left front inside corner.  Crack is typical for a house of this age.  There was no related cracking noted in the foundation during the crawlspace inspection in this location.   No action required at this time.  Recommend monitoring crack for movement.  If movement is noted then further action may be required.

2.0 Picture 4

2.0 Picture 5

2.0 Picture 6

2.0 Picture 7
2.1 Dead bolts for exterior doors require a key to operate.  It is recommended that these be replaced with lever operated dead bolts to allow egress in an emergency (fire) without a key.

2.1 Picture 1

2.1 Picture 2
2.5 Negative slope towards right side (facing front)and left front corner near downspout. These areas do not appear to drain water away from home and needs landscaping and drainage corrected. See photos with water draining into the crawlspace.

2.5 Picture 1

2.5 Picture 2

2.5 Picture 3

2.5 Picture 4

Vegetation is in contact with the house.  Keep all vegetation trimmed away from siding and roof to reduce the possibility of water and insect damage.
2.6 Roof leak has caused water damage to the soffit at the left, front  and right of the porch, water is also entering into the wall cavity and onto the living room ceiling.  See the roofing section for more discussion.  Recommend having a qualified contractor or roofer  make the appropriate repairs

Note: picture 2 is an after improvement photo.



2.6 Picture 1

2.6 Picture 2
2.7 Condition of vegetation is average.

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email atbruce@yourhomeanalyst.com.




ROOFING

GAHI Limitations for Roof, Guttering and Other Roof  Components

The Inspector is not required to:

  1. Perform tasks that place them in danger or may cause property damage.
  2. Walk on roof.
  3. Inspect or report on accessory items not listed below (such as antennae, solar panels, etc.)
  4. Estimate the remaining life of roof covering, flashing, caulking materials, or other components.
  5. Handle or disturb materials suspected of containing hazardous material.

Styles & Materials
CHIMNEY (exterior):
N/A
VIEWED ROOF COVERING FROM:
GROUND
ROOF COVERING:
3-TAB FIBERGLASS
ROOF STYLE:
HIP
GABLE
ROOF PITCH:
MEDIUM
SKY LIGHT (S):
NONE
FLASHING:
NOT PRESENT

 INNINPCRR
3.0 ROOF COVERINGSX   X
3.1 FLASHINGSX    
3.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONSX   X
3.3 ROOFING DRAINAGE SYSTEMS, GUTTERS& DOWNSPOUTSX    
3.4 AREAS OF ROOF NOT VISIBLEX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
3.0 Repair damaged shingles at rear roof corners, left side roof just above eve the gutter and at front valley over the front porch.

High level of moisture indicating active leaking from this location into the interior walls was found on the ceiling and above the front windows (see photos). Ma

Recommend having a qualified roofer make the appropriate repairs.

For location(s) see photo(s):

Note: pictures 7 - 9 are after improvement photos.



3.0 Picture 1

3.0 Picture 2

3.0 Picture 3

3.0 Picture 4

3.0 Picture 5

3.0 Picture 6

3.0 Picture 7

3.0 Picture 8

3.0 Picture 9
3.2 Flue or vent boot flashing has lifted and needs to be reset to the roof and sealed.

For details and/or examples see photo(s):

Note: pictures 2 - 3 are after improvement photos.



3.2 Picture 1

3.2 Picture 2

3.2 Picture 3

Roof leak in the area of the electrical mast.  Water seen dripping at trim board below.  For details and/or examples see photo(s):

3.2 Picture 4

3.2 Picture 5
3.3 Downspout needs extension and a buried drain line to carry water away from home at front and left of main entry.
3.4 None

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email atbruce@yourhomeanalyst.com.




PLUMBING SYSTEM

GAHI Limitations for Plumbing

The Inspector is not required to:

  1. Operate systems that have been shut-down or winterized.
  2. Operate temperature/pressure relief valves.
  3. Determine the adequacy of flow in more than one room at a time.
  4. Report on condition of septic tanks, related system components, and/or sewage lift systems.

Styles & Materials
WATER SOURCE:
PUBLIC
WATER FILTERS:
NONE
PLUMBING SUPPLY:
COPPER
PLUMBING DISTRIBUTION:
COPPER
WASHER DRAIN SIZE:
2" DIAMETER
PLUMBING WASTE:
CAST IRON (OLD)
WATER HEATER POWER SOURCE:
GAS (QUICK RECOVERY)
CAPACITY:
40 GAL (1-2 PEOPLE)
MANUFACTURER:
RHEEM
AGE OF WATER HEATER:
2000

 INNINPCRR
4.0 INTERIOR WATER PRESSURE (record pressure) X   
4.1 INTERIOR WATER SUPPLY, DISTRIBUTION SYSTEMS AND FIXTURES X   
4.2 SHOWER / TUB SURROUNDS AND ENCLOSURESX   X
4.3 HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES, VENTS, AND RELIEF SYSTEMSX    
4.4 INTERIOR DRAIN, WASTE AND VENT SYSTEMS X  X
4.5 FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks)X    
4.6 SUMP PUMPX   X
4.7 LOCATION OF WASHER / DRYER CONNECTIONSX    
4.8 LOCATION OF MAIN FUEL SHUT OFF VALVEX    
4.9 MAIN WATER SHUT-OFF DEVICE (Describe location)X    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
4.0 Water was shut off at time of the inspection. Water pressure should be between 40 psi and 80 psi.
4.1 Water was shut off at time of the inspection.
4.2 Seal the tub and tile floor joint with a high quality sealant to prevent water intrusion and subsequent damage to flooring material and structural components.
4.3 This is a 2000 installation and the following requirement was not in effect.  Any water heater installed or replaced after January 1, 2001   is required to have either a water pressure tank or relief valve.  Have a qualified plumber properly install a pressure tank or relief valve.

Code IPC GA Amended 607.3.2 Backflow prevention Device or check valve.  Where a backflow prevention device, check valve or other device is installed on a water supply system utilizing storage water heating equipment such that thermal expansion causes an increase in pressure, a device for controlling pressure shall be installed.  The device shall limit thermal expansion of the water being heated to not more than 80 pounds per square inch static pressure at any fixture on the system.  A potable water expansion tank, or auxiliary relief valve or other approved device that limits pressure to 80 psi or less shall be acceptable.  It shall be installed in accordance with manufacturer's instructions. (Effective January 1, 2001).

4.4 Unable to test system for leaks.  Water was shut off at time of inspection.
Toilet is loose at floor . Repair may involve resetting the toilet on a new wax seal at Master Bath.
PVC line with damaged cover.  Clean out the pipe, determine use and properly cover.

4.4 Picture 1
4.6 Visible signs of water intrusion in crawlspace are present and a"Sump Pump" is installed. Existing sump pump makes loud noise at times when tested.  A bearing may be failing requiring repair or replacement of the pump and or motor.  Unable to determine the extent of intrusion or how often it occurs.  Sump was dry at time of inspection.

4.6 Picture 1
4.7 Located in the kitchen. 
4.8 See photo 1 for location of main fuel shut off valve.

4.8 Picture 1
4.9 See photo 1 for location of main water valve.

4.9 Picture 1

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email atbruce@yourhomeanalyst.com.




ELECTRICAL SYSTEMS

GAHI Limitations for Electrical

The Inspector is not required to:

  1. Insert any tool, probe or testing device into the main or sub-panels.
  2. Activate electrical systems or branch circuits that are not energized.
  3. Operate overload protection devices except GFCI and AFCI breakers.
  4. Move objects to gain access to electrical outlets. switches or panels etc.
  5. Inspect equipment that is not readily accessible or dismantle equipment or components.
  6.  Remove switch or receptacle covers nor unplug or disconnect electrical devices.
  7. Test GFCI or AFCI devices by any means other than that provided by the manufacturer.
  8. Test GFCI or AFCI devices when in the inspector's opinion doing so could endanger persons or damage property.
  9. Test a smoke detector by any means other than that provided by the manufacturer.

Styles & Materials
ELECTRICAL CONDUCTORS:
ABOVE GROUND
ALUMINUM
220 VOLTS
PANEL CAPACITY:
150 AMP
PANEL TYPE:
CIRCUITS
ELEC. PANEL MANUFACTURER:
GOULD
BRANCH WIRE 15 and 20 AMP:
COPPER
WIRING METHODS:
ROMEX

 INNINPCRR
5.0 SERVICE ENTRANCE CONDUCTORSX    
5.1 SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELSX   X
5.2 BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGEX   X
5.3 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)X   X
5.4 POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTUREX    
5.5 OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)X    
5.6 SMOKE DETECTORSX    
5.7 LOCATION OF MAIN AND DISTRIBUTION PANELSX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
5.1 Distribution panel has open spaces (knock-outs for circuit breakers).  These openings pose a safety hazard and must be covered with appropriate covers.  Recommend installing approved slot covers.

For details and/or examples see photo(s):



5.1 Picture 1

Unable to locate system ground. Recommend having a qualified licensed electrician test system grounding and repairs as necessary.
5.2 Wires entering junction box(s) are not properly or are missing clamps.  Recommend having a qualified licensed electrician make the appropriate repairs and or replacements.

For details and/or examples see photo(s):



5.2 Picture 1

5.2 Picture 2

5.2 Picture 3
5.3 Open ground in outlets to the left and right of the kitchen sink, hall bath and den (den outlet is also loose at wall). Recommend having a qualified licensed electrician make the appropriate repairs and or replacements.

For details and/or examples see photo(s):

Note: pictures 5 is an after improvement photo.



5.3 Picture 1

5.3 Picture 2

5.3 Picture 3

5.3 Picture 4

5.3 Picture 5
5.7 Main breaker is located in the distribution panel / box which is located in the kitchen.

5.7 Picture 1

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email atbruce@yourhomeanalyst.com.




HEATING

GAHI Limitations for Heating and Cooling Equipment and Systems

The Inspector is not required to:

  1. Ignite or extinguish fires, disassemble flue piping, determine draft characteristics, or move fireplace inserts or stoves or firebox contents.
  2. Activate equipment that has been "shut-down" or will not respond to thermostat controls or otherwise deactivated.
  3. Operate cooling equipment when the ambient temperature has been less than 65 F within the previous 24 hours.
  4. Access equipment by any means other than panels provided by the manufacturer for inspection and/or service.
  5. Determine the efficiency of the system or distribution or equipment.
  6. Inspect or report on humidifiers or electronic air cleaners.
  7. Inspect the interior of flues or chimneys that are not readily accessible.
  8. Inspect fire screens or doors, seals or gaskets, mantles and surround, make up air devices or heat distribution assist systems.

Styles & Materials
HEAT TYPE:
FORCED AIR
ENERGY SOURCE:
GAS
NUMBER OF HEAT SYSTEMS (excluding wood):
ONE
HEAT SYSTEM BRAND:
GOODMAN
DUCTWORK:
INSULATED
And
NON-INSULATED
POSSIBLE ASBESTOS TAPE AROUND CONNECTIONS
FILTER TYPE:
DISPOSABLE
FILTER SIZE:
20x20
TYPES OF FIREPLACES:
NONE
OPERABLE FIREPLACES:
NONE
NUMBER OF WOODSTOVES:
NONE
FURNACE BTU/HR.:
75000
APPROXIMATE AGE:
2003

 INNINPCRR
6.0 HEATING EQUIPMENTX   X
6.1 HEATING EQUIPMENT LOCATIONX    
6.2 NORMAL OPERATING CONTROLS X   
6.3 AUTOMATIC SAFETY CONTROLSX    
6.4 CHIMNEYS, FLUES AND VENTSX   X
6.5 HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)X   X
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
6.0 Flex gas line is not permitted to pass thorough the furnace sidewall.  Have a qualified plumber or HVAC technician install the proper gasket or rigid pipe to pass through the furnace side wall in accordance with the manufacturer's instructions.  See white tag on gas line.

6.0 Picture 1
6.1 In the crawlspace.
6.2 System operation not inspected as gas was shut off.
6.4 Furnace flue dips and does not maintain proper rise.  Have qualified HVAC contractor make appropriate repairs.  See photo for location.

6.4 Picture 1
6.5 Multiple gaps holes and disconnected sections of the supply and return ducts were found in the crawlspace.  Have a qualified HVAC contractor make the appropriate repairs and or replacements.  See photos for details.

Note: pictures 7 - 8 are after improvement photos.



6.5 Picture 1

6.5 Picture 2

6.5 Picture 3

6.5 Picture 4

6.5 Picture 5

6.5 Picture 6

6.5 Picture 7

6.5 Picture 8

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email atbruce@yourhomeanalyst.com.




CENTRAL AIR CONDITIONING

Styles & Materials
NUMBER OF A/C UNITS:
ONE
COOLING EQUIPMENT TYPE:
AIR CONDITIONER UNIT
COOLING EQUIPMENT ENERGY SOURCE:
ELECTRICITY
CENTRAL AIR MANUFACTURER:
GOODMAN
COOLING EQUIPMENT CAPACITY IN TONS:
3.0
AGE OF COMPRESSOR (S):
2000

 INNINPCRR
7.0 COOLING EQUIPMENT LOCATIONX    
7.1 COOLING AND AIR HANDLER EQUIPMENT X   
7.2 NORMAL OPERATING CONTROLS X   
7.3 DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)X    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
7.0 AC units are located on the right side of the house.
7.1 The AC system was not tested for proper operation due to the outside air temperature was 65 degrees or less during the past 24 hour period.. According to AC manufacturers, running the AC compressor while the oil inside the compressor is cold can result in damage to the valves and cause irreparable scoring damage to the compressor.  Additionally, accurate test results are not possible below this temperature.

The AC should be tested when the outside temperature has been above 65 degrees for 24 hours.  Ensure that there is a 14 to 20 degree temperature drop.  This temperature drop is measured by comparing supply duct and return air duct temperatures.  Have a qualified HVAC technician inspect the system, add cooling fluid if necessary and ensure that the temperature drop is appropriate.

7.3 See heating section for discussion and recommendations.



INTERIORS

GAHI Limitations for General Interior

The Inspector is not required to:

  1. Move furniture or owners possessions.
  2. Enter rooms where pets are loose.

Styles & Materials
CEILING MATERIALS:
SHEETROCK
WALL MATERIAL:
SHEETROCK
FLOOR COVERING(S):
HARDWOOD T&G
LINOLEUM
TILE
WOOD
INTERIOR DOORS:
HOLLOW CORE
CABINETRY:
WOOD
COUNTERTOP:
LAMINATE

 INNINPCRR
8.0 CEILINGSX    
8.1 WALLSX   X
8.2 FLOORSX   X
8.3 DOORS (REPRESENTATIVE NUMBER)X   X
8.4 WINDOWS (REPRESENTATIVE NUMBER)X   X
8.5 STEPS, STAIRWAYS, BALCONIES AND RAILINGSX    
8.6 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS AND DRAWERSX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
8.0 See roofing section for comments regarding wet water stains indicating active leaks.
8.1 Fixture over master bath sink is broken,  Edges are sharp and the fixture should be replaced.

Note: picture 2 is an after improvement photo.



8.1 Picture 1

8.1 Picture 2

Hole in wall under master bath sink cabinet from plumbing repairs.

8.1 Picture 3
8.2 Floor in hall bath has dropped.  See structural floor section for more detailed discussion.

Note: picture 2 is an after improvement photo.



8.2 Picture 1

8.2 Picture 2
8.3 Privacy door needs doorknob and hardware repaired or replace to work properly at bedroom and den.

8.3 Picture 1

8.3 Picture 2
8.4 Glass is not safety glass or identifiable as safety glass.  Although not a requirement at the time the house was built, glass at hazardous locations (next to door and door glass panels) should be safety / tempered glass.   Recommend changing glass in these areas to safety glass.  The following code is provided as a courtesy to the buyers.  Note:   This would be considered an upgrade, however it is considered a safety item.

8.4 Picture 1

Broken glass pane near sunroom rear door.  Recommend replacement of glass pane.

8.4 Picture 2

 Windows are painted shut.  It is important that windows operate freely as they provide the secondary means of egress from the house in the event of fire or other emergency.

8.4 Picture 3

8.4 Picture 4

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email atbruce@yourhomeanalyst.com.




INSULATION AND VENTILATION

GAHI Limitations for Insulation and Ventilation

The Inspector is not required to:

  1. Evaluate ventilation Adequacy by any means other than visual.
  2. Evaluate the efficiency of insulation.

Styles & Materials
R- VALUE:
BELOW R-19
ATTIC INSULATION:
BLOWN
CELLULOSE
EXHAUST FAN TYPES:
FAN ONLY
DRYER POWER SOURCE:
22O ELECTRIC
GAS CONNECTION
DRYER VENT:
METAL
ATTIC VENTILATION:
GABLE VENTS
SOFFIT VENTS
Thermostatically controlled fan

 INNINPCRR
9.0 INSULATION AND VAPOR RETARDERS (in unfinished spaces)X    
9.1 VENTILATION OF ATTIC AND FOUNDATION AREASX   X
9.2 VENTING SYSTEMS (Kitchens, baths and laundry)X   X
9.3 VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC)X   X
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
9.0 No insulation of floor system.
9.1 Several screens in crawlspace vents are damaged or missing.  Repair or replace.

9.1 Picture 1
9.2 Exhaust fan is noisy and needs cleaning or possible repair or replacement at hall hath.

9.2 Picture 1

Dryer vent has disconnected from outside fitting, pulled vent screen loose and has dumped excess moisture and lint into the crawlspace.  Repair or replace dryer vent.

9.2 Picture 2
9.3 Thermostatically controlled"Vent fan" in attic is defective (fan blade no longer turns easily). Motor and possibly unit, will most likely need to be replaced.

9.3 Picture 1

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email atbruce@yourhomeanalyst.com.




BUILT-IN KITCHEN APPLIANCES

GAHI Limitations for Kitchen and Appliances

The Inspector is not required to:

  1. Check calibration of temperature or determine that the oven-heated temperature correspond to the control setting.
  2. Determine the efficiency of any equipment.
  3. Determine the remaining life of any equipment.
  4. Test or operate any equipment other than the outlined below.
  5. Test or inspect timer and/or other accessory type controls
  6. Inspector is not required to check microwave ovens for radiation leaks.
  7. Inspector is not required to operate or inspect trash compactors.
  8. Inspector is not required to inspect refrigerators.

Styles & Materials
DISHWASHER:
MAGIC CHEF
DISPOSER:
NONE
EXHAUST/RANGE HOOD:
NUTONE
RANGE/OVEN:
HOTPOINT
BUILT-IN MICROWAVE:
NONE
TRASH COMPACTORS:
NONE
REFRIGERATOR:
MAGIC CHEF

 INNINPCRR
10.0 DISHWASHER X   
10.1 RANGES/OVENS/COOKTOPS X   
10.2 RANGE HOODX    
10.3 TRASH COMPACTOR  X  
10.4 FOOD WASTE DISPOSER  X  
10.5 BUILT IN MICROWAVE COOKING EQUIPMENT  X  
10.6 REFRIGERATOR X   
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
10.0 Dish washer will be replaced. Not inspected
10.1 No gas at time of inspection.
10.6 Refrigerator may be replaced. Not inspected.

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email atbruce@yourhomeanalyst.com.




COMPLIMENTARY PHOTO VIEWS

 
 INNINPCRR
11.0 ATTIC VIEWX    
11.1 DEN VIEWX    
11.2 HALL BATH VIEWX    
11.3 LIVING ROOM VIEWX    
11.4 MASTER BEDROOM VIEWX    
11.5 MASTER BATH VIEWX    
11.6 SUNROOMX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:

11.0 View of Attic

11.0 Picture 1
11.1 Den View

11.1 Picture 1
11.2 Hall Bath View

11.2 Picture 1
11.3 Living Room View

11.3 Picture 1
11.4 Master Bedroom View

11.4 Picture 1
11.5 Master Bath View

11.5 Picture 1
11.6 Sunroom view

11.6 Picture 1

Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To Home Analyst, Inc.



Summary of Inspection Report


Home Analyst, Inc.

P.O. Box 670774
Marietta, GA 30066
404-978-2266
Bruce@yourhomeanalyst.com

Customer
Recycled Homes, Inc.

Property Address
3409 New Home Drive
Sandy Springs, GA 30355

The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or appear to warrant further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

STRUCTURAL COMPONENTS
1.0 FOUNDATIONS (Structural)
 Inspected, Repair or Replace
 
Crack in wall at rear of home. The appearance of settlement crack is not large enough for concern. Recommend filling void area to prevent additional cracking.
1.1 FLOORS (Structural)
 Inspected, Repair or Replace
 
Bathroom floor has dropped due to damage to girder below in crawlspace.  Make repairs as necessary to the girder.  Ensure that the floor to tub joint is well sealed to prevent water penetration to the framing below.  See photos for details

Note: pictures 6 - 8 are after improvement photos.

1.5 ATTIC AND ROOF STRUCTURE
 Inspected, Repair or Replace
 
Pull down stairs is too long.  This places too much pressure on the joint.  To improve safety and stability of the ladder shorten attic stairs so that the sides of the ladder make a straight line..
1.6 CRAWLSPACE
 Inspected, Repair or Replace
 
Remove building debris from crawlspace.  See photos for examples.

Note: picture 4 is an after improvement photo.


EXTERIOR
2.0 WALL CLADDING, FLASHING AND TRIM
 Inspected, Repair or Replace
 
Stone veneer at left front corner has come loose.  This stone (see photo 1) supported a brick lentil and brick veneer.  Brick veneer has cracked.  The damage does not involve the foundation.  Have a qualified contractor or mason make the appropriate repairs.

Note: picture 2  is an after improvement photo.

2.5 VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building and it's systems)
 Inspected, Repair or Replace
 
Negative slope towards right side (facing front)and left front corner near downspout. These areas do not appear to drain water away from home and needs landscaping and drainage corrected. See photos with water draining into the crawlspace.
 
Vegetation is in contact with the house.  Keep all vegetation trimmed away from siding and roof to reduce the possibility of water and insect damage.
2.6 EAVES, SOFFITS AND FASCIAS
 Inspected, Repair or Replace
 
Roof leak has caused water damage to the soffit at the left, front  and right of the porch, water is also entering into the wall cavity and onto the living room ceiling.  See the roofing section for more discussion.  Recommend having a qualified contractor or roofer  make the appropriate repairs

Note: picture 2 is an after improvement photo.

2.7 GROUND COVER& VEGETATION (condition)
 Inspected, Repair or Replace
 
Condition of vegetation is average.

ROOFING
3.0 ROOF COVERINGS
 Inspected, Repair or Replace
 
Repair damaged shingles at rear roof corners, left side roof just above eve the gutter and at front valley over the front porch.

High level of moisture indicating active leaking from this location into the interior walls was found on the ceiling and above the front windows (see photos). Ma

Recommend having a qualified roofer make the appropriate repairs.

For location(s) see photo(s):

Note: pictures 7 - 9 are after improvement photos.

3.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS
 Inspected, Repair or Replace
 
Flue or vent boot flashing has lifted and needs to be reset to the roof and sealed.

For details and/or examples see photo(s):

Note: pictures 2 - 3 are after improvement photos.

 
Roof leak in the area of the electrical mast.  Water seen dripping at trim board below.  For details and/or examples see photo(s):

PLUMBING SYSTEM
4.1 INTERIOR WATER SUPPLY, DISTRIBUTION SYSTEMS AND FIXTURES
 Not Inspected
 
Water was shut off at time of the inspection.
4.2 SHOWER / TUB SURROUNDS AND ENCLOSURES
 Inspected, Repair or Replace
 
Seal the tub and tile floor joint with a high quality sealant to prevent water intrusion and subsequent damage to flooring material and structural components.
4.4 INTERIOR DRAIN, WASTE AND VENT SYSTEMS
 Not Inspected, Repair or Replace
 
Unable to test system for leaks.  Water was shut off at time of inspection.
 
Toilet is loose at floor . Repair may involve resetting the toilet on a new wax seal at Master Bath.
 
PVC line with damaged cover.  Clean out the pipe, determine use and properly cover.
4.6 SUMP PUMP
 Inspected, Repair or Replace
 
Visible signs of water intrusion in crawlspace are present and a"Sump Pump" is installed. Existing sump pump makes loud noise at times when tested.  A bearing may be failing requiring repair or replacement of the pump and or motor.  Unable to determine the extent of intrusion or how often it occurs.  Sump was dry at time of inspection.

ELECTRICAL SYSTEMS
5.1 SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS
 Inspected, Repair or Replace