Home Analyst, Inc.

P.O. Box 670774
Marietta, GA 30066
404-978-2266
Bruce@yourhomeanalyst.com

Customer
Jane Homebuyer

Home
123 Shady Lane
Powder Springs, GA 30127

Real Estate Agent
John H. Onest
Best Homes

Inspection Date: 
7/5/2006
 
Weather:
Clear
Report ID:
06070501-homebuyer
Temperature:
81
Inspected By:
Bruce Rickey



Date: 7/5/2006 Time: 9:18 AM Report ID: 06070501-homebuyer
Property:
123 Shady Lane
Powder Springs, GA 30127
Customer:
Jane Homebuyer
Real Estate Professional:
John H. Onest
Best Homes

This inspection was performed for the home owner selling this home and was inspected according to ASHI and GAHI standards and practices. The comments made in this report were based on the condition of the home at time of inspection. There is no warranty from the inspection company. For a fee, our company can return and review the inspection, or inspect the home again. The proposed buyer can hire a different inspector if desired. Different inspectors can find different things sometimes on the same home. Home Analyst, Inc. is not responsible for any discoveries included or not found. As this inspection report ages, the condition of this home and its components can change. 

Thank you for the opportunity to be of service,

Bruce Rickey

Owner

Home Analyst, Inc.

Homes more than 5 years old may have areas that are not current in code requirements. This is not a new home and this home cannot be expected to meet current code standards. While this inspection makes every effort to point out safety issues, it does not inspect for code. It is common that homes of any age will have had repairs performed and some repairs may not be in a workmanlike manner. Some areas may appear less than standard. This inspection looks for items that are not functioning as intended. It does not grade the repair. It is sometimes common to see old plumbing or mixed materials. Sometimes water signs in crawlspaces or basements could be years old from a problem that no longer exists. Or, it may still need further attention and repair. Determining this can be difficult in occupied home. Sometimes homes have signs of damage to wood from wood eating insects. Having this is typical and fairly common. If the home inspection reveals signs of damage you should have a pest control company inspect further for activity and possible hidden damage. The home inspection does not look for possible manufacturer re-calls on components that could be in this home. Always consider hiring the appropriate expert for any repairs or further inspection.

Client Is Present:
Yes

Age Of Home:
1993

Radon Test:
No

Water Test:
No

Weather:
Clear

Temperature:
81

Rain in last 3 days:
Yes




STRUCTURAL COMPONENTS

GAHI Limitations for Structural Components

The Inspector is not required to:

  1. Enter crawl spaces with headroom less than two feet or where adverse conditions exist.
  2. Move stored items or debris.
  3. Enter areas that may contain hazardous materials.
  4. Determine the extent of damage by insects or water.
  5. Operate sump pumps or drainage systems.
  6. Enter attic spaces where the headroom is less than 30 inches.
  7. Enter attic spaces where hazardous conditions exist.

 

Styles & Materials
FOUNDATION:
POURED CONCRETE
FLOOR STRUCTURE:
SLAB
WALL STRUCTURE:
2 X 4 WOOD
COLUMNS OR PIERS:
SUPPORTING WALLS
CEILING STRUCTURE:
2X10
ROOF STRUCTURE:
STICK-BUILT
2 X 8 RAFTERS
LATERAL BRACING
SHEATHING
ROOF-TYPE:
GABLE
ATTIC ACCESS TYPES PRESENT:
DROP-DOWN STAIRS
ATTIC ACCESS LOCATIONS:
GARAGE

 INNINPCRR
1.0 FOUNDATIONS (Structural)X    
1.1 FLOORS (Structural)X    
1.2 WALLS (Structural)X    
1.3 COLUMNS OR PIERSX    
1.4 CEILINGS (Structural)X    
1.5 ATTIC AND ROOF STRUCTUREX   X
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
1.0 Roof rafters bracing is inadequate and the rafters are sagging.  Lateral bracing (purlins) and purlin braces are not properly installed. The purlins should be continuous and the braces must be placed four feet on center. 

For details and/or examples see photo(s):

1.5 Roof rafters bracing is inadequate and the rafters are sagging.  Lateral bracing (purlins) and purling braces are not properly installed. The purlins should be continuous and the braces must be placed four feet on center. 

For details and/or examples see photo(s):



1.5 Picture 1

1.5 Picture 2

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report, please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email at info@yourhomeanalyst.com.




EXTERIOR

GAHI Limitations for Grounds and Appurtenances

The Inspector is not required to:

  1. Identify or report the observed condition of: fences (except if around a swimming pool); playground or other recreational equipment; fire or lawn sprinklers; swimming pool; spas or jetted tubs; below ground drainage or septic systems; water wells; out buildings or storage buildings except detached garages.
  2. Determine property line boundaries, soil, or geological conditions.

GAHI Limitations for Building Exterior

The Inspector is not required to:

  1. Report on the adaquacy of storm windows or storm doors.
  2. Report on the quality or contents of the paint.
  3. Inspect or report on decks or other structures that are not attached to the dwelling.
  4. Report on the presence of screens.
  5. Identify the method of treatment of any preservative treated lumber.
  6. Identify the type/method of corrosion resistance of any fastners or connectors and/or the suitability of use of any fasteners or connectors with any preservative treated lumber.

GAHI Limitations for Garage/Carport

The Inspector is not required to:

  1. Operate door openers that have been disconnected from the power source.
  2. Operate doors if animals are loose in a garage.

Styles & Materials
DECK (S):
WOOD
DRIVEWAY:
CONCRETE
EXTERIOR ENTRY DOORS:
STEEL
SIDING STYLE:
LAP
GARAGE LOCATION:
ATTACHED
GARAGE DOOR MATERIAL:
METAL
GARAGE DOOR OPENER MANUFACTURER:
GENIE
GARAGE DOOR TYPE:
TWO AUTOMATIC
PORCH (S):
CONCRETE
SIDING MATERIAL:
COMPOSITE BOARD
WINDOW TYPES:
THERMAL/INSULATED
SINGLE-HUNG
METAL
WINDOW MANUFACTURER:
UNKNOWN
WALKWAYS:
CONCRETE

 INNINPCRR
2.0 WALL CLADDING, FLASHING AND TRIMX    
2.1 DOORS (Exterior)X   X
2.2 WINDOWSX  XX
2.3 STORM DOORS AND WINDOWS  X  
2.4 GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance)X    
2.5 GARAGE SAFETYX    
2.6 DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGSX    
2.7 VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building and it's systems)X   X
2.8 EAVES, SOFFITS AND FASCIASX    
2.9 GROUND COVER& VEGETATION (condition)X    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
2.0 Louisiana Pacific siding has  been the subject of a class action lawsuit.  Please view the following website for more complete information about the status of the suit and issues concerning this type of siding.  http://www.lpsidingclaims.com/ 
2.1 The wood door frame to metal threshold joint is not adequately caulked.  Failure to adequately seal this area may lead to rotting of the wood door frame.  This is especially important where the door and threshold will be exposed to the elements.  It is recommend that all of the factory glue squeeze out be removed, clean all surfaces of dirt and loose paint, prime area if necessary and seal with a high quality paintable sealant.

2.1 Picture 1
2.2 Thermal windows have lost their seal and have begun to cloud.  Repair or replace windows with damaged seals.

For details and/or examples, see photo(s):



2.2 Picture 1

2.2 Picture 2

2.2 Picture 3

2.2 Picture 4

2.2 Picture 5

2.2 Picture 6

2.2 Picture 7
2.4 Both garage doors will reverse when met with resistance.
2.7 Grade is too high. Dirt is in contact with the siding and/or trim of the house.  This can lead to water damage, rot and insect damage.  Ideally, the grade should be 6" below the bottom of the siding.  This makes it easy to inspect the foundation for insect activity and helps to prevent termites and water-related damage.  It is recommended that the dirt be removed and that final grading directs water drainage away from the house.

2.7 Picture 1

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report, please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email at info@yourhomeanalyst.com.




ROOFING

GAHI Limitations for Roof, Guttering and Other Roof  Components

The Inspector is not required to:

  1. Perform tasks that place them in danger or may cause property damage.
  2. Walk on roof.
  3. Inspect or report on accessory items not listed below (such as antennae, solar panels, etc.)
  4. Estimate the remaining life of roof covering, flashing, caulking materials, or other components.
  5. Handle or disturb materials suspected of containing hazardous material.

Styles & Materials
CHIMNEY (exterior):
COMPOSITION BOARD
VIEWED ROOF COVERING FROM:
BINOCULARS
GROUND
LADDER
ROOF COVERING:
3-TAB FIBERGLASS
ROOF STYLE:
HIP
ROOF PITCH:
STEEP
SKY LIGHT (S):
NONE
FLASHING:
ALUMINUM
GALVANIZED STEEL

 INNINPCRR
3.0 ROOF COVERINGSX   X
3.1 FLASHINGSX    
3.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONSX    
3.3 ROOFING DRAINAGE SYSTEMS, GUTTERS& DOWNSPOUTSX    
3.4 AREAS OF ROOF NOT VISIBLEX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
3.0 Nail pops or other debris under shingle(s). Recommend having a qualified roofer make the appropriate repairs.

For examples see photos:



3.0 Picture 1

3.0 Picture 2

3.0 Picture 3
3.1 The roof is improperly flashed.  Single piece flashing and a modified flashing has been installed. Step-flashing should have been installed at the time the roof was installed.  Due to the age of the roof and since there was no visible evidence of roof leaks, installing step-flashing at this time is not recommended.  When the roof is replaced in the future, ensure that the roofer properly installs step-flashing as required by code when over 50% of the roofing is replaced.  The following code has been provided for the buyer's convenience.

 

CODE ICC R905.2.8.4 Sidewall flashing. Flashing against a vertical sidewall shall be by the step-flashing method.

For details and/or examples, see photo(s):

Website: Roof Flashing http://www.ibacos.com/pubs/RoofFlashingGuidelines.pdf


3.1 Picture 1

3.1 Picture 2

3.1 Picture 3

3.1 Picture 4
3.3 Gutter is rusted and deteriorated in various areas throughout. Should be replaced when the roof is replaced or when leaks develop.

3.3 Picture 1
3.4 None

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report, please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email at info@yourhomeanalyst.com.




PLUMBING SYSTEM

GAHI Limitations for Plumbing

The Inspector is not required to:

  1. Operate systems that have been shut-down or winterized.
  2. Operate temperature/pressure relief valves.
  3. Determine the adequacy of flow in more than one room at a time.
  4. Report on condition of septic tanks, related system components, and/or sewage lift systems.

Styles & Materials
WATER SOURCE:
PUBLIC
WATER FILTERS:
NONE
PLUMBING SUPPLY:
POLY
PLUMBING DISTRIBUTION:
POLY
WASHER DRAIN SIZE:
2" DIAMETER
PLUMBING WASTE:
PVC
WATER HEATER POWER SOURCE:
GAS (QUICK RECOVERY)
CAPACITY:
40 GAL (1-2 PEOPLE)
MANUFACTURER:
GE
AGE OF WATER HEATER:
2004

 INNINPCRR
4.0 EXTERIOR PLUMBING SYSTEMSX   X
4.1 INTERIOR WATER PRESSURE (record pressure)X   X
4.2 SHOWER / TUB SURROUNDS AND ENCLOSURESX   X
4.3 INTERIOR WATER SUPPLY, DISTRIBUTION SYSTEMS AND FIXTURESX    
4.4 INTERIOR DRAIN, WASTE AND VENT SYSTEMSX    
4.5 FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks)X    
4.6 LOCATION OF WASHER / DRYER CONNECTIONSX    
4.7 LOCATION OF MAIN FUEL SHUT OFF VALVEX    
4.8 MAIN WATER SHUT-OFF DEVICE (Describe location)X    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
4.0 Hose bib is not properly anchored to the house siding. Recommend having a qualified plumber make the appropriate repairs and or replacements.  Near garage door.

4.0 Picture 1
4.1 Water pressure should be between 40 psi and 80 psi and when tested was found to be at 95 psi. The water pressure is too high.

Excessive pressure can cause damage to fixtures and fittings.  Have a qualified plumber adjust and or repair the pressure reducing valve as necessary to maintain house pressure between 40 and 80 psi.

4.2 Active leak at shower resulting in stain.  Water was seen leaking up between edge of vinyl and tile in area circled in photo.  Have a qualified repair company make appropriate repairs to damaged areas to prevent further leaks.

4.2 Picture 1
4.3 Polybutylene plastic plumbing supply lines (PB) are installed in the subject house. Polybutylene has been used in this area for many years, but has had a higher than normal failure rate, and is no longer being widely used. Copper and brass fittings used in later years have apparently reduced the failure rate. This subject house has copper fittings. For further details, contact the Consumer Plumbing Recovery center at 1-800-392-7591 or the web at http://www.pbpipe.com.
4.6 See photos for location of washer and dryer connections.

4.6 Picture 1

4.6 Picture 2
4.7 See photo 1 for location of main fuel shut off valve.

4.7 Picture 1
4.8 See photo 1 for location of main water valve. The main shut-off is the white lever beside water heater.

4.8 Picture 1

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report ,please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email at info@yourhomeanalyst.com.




ELECTRICAL SYSTEMS

GAHI Limitations for Electrical

The Inspector is not required to:

  1. Insert any tool, probe or testing device into the main or sub-panels.
  2. Activate electrical systems or branch circuits that are not energized.
  3. Operate overload protection devices except GFCI and AFCI breakers.
  4. Move objects to gain access to electrical outlets. switches or panels, etc.
  5. Inspect equipment that is not readily accessible or dismantle equipment or components.
  6. Remove switch or receptacle covers nor unplug or disconnect electrical devices.
  7. Test GFCI or AFCI devices by any means other than that provided by the manufacturer.
  8. Test GFCI or AFCI devices when in the inspector's opinion doing so could endanger persons or damage property.
  9. Test a smoke detector by any means other than that provided by the manufacturer.

Styles & Materials
ELECTRICAL CONDUCTORS:
BELOW GROUND
ALUMINUM
220 VOLTS
PANEL CAPACITY:
150 AMP
PANEL TYPE:
CIRCUITS
ELEC. PANEL MANUFACTURER:
SIEMENS
BRANCH WIRE 15 and 20 AMP:
COPPER
WIRING METHODS:
ROMEX

 INNINPCRR
5.0 SERVICE ENTRANCE CONDUCTORSX    
5.1 SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELSX    
5.2 BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGEX    
5.3 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)X   X
5.4 POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTUREX    
5.5 OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)X    
5.6 SMOKE DETECTORSX    
5.7 OPERATION OF AFCI (Arc Fault) BREAKERSX    
5.8 LOCATION OF MAIN AND DISTRIBUTION PANELSX    
5.9 LOCATION OF ELECTRICAL SYSTEM GROUNDX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
5.3 Door bell does not operate.
5.8 Main panel box is located at garage. However, main disconnect (shut-off) is outside at meter base panel (for your information).

5.8 Picture 1

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report, please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email at info@yourhomeanalyst.com.




HEATING

GAHI Limitations for Heating and Cooling Equipment and Systems

The Inspector is not required to:

  1. Ignite or extinguish fires, disassemble flue piping, determine draft characteristics, or move fireplace inserts or stoves or firebox contents.
  2. Activate equipment that has been "shut-down" or will not respond to thermostat controls or otherwise deactivated.
  3. Operate cooling equipment when the ambient temperature has been less than 65 degrees F within the previous 24 hours.
  4. Access equipment by any means other than panels provided by the manufacturer for inspection and/or service.
  5. Determine the efficiency of the system or distribution or equipment.
  6. Inspect or report on humidifiers or electronic air cleaners.
  7. Inspect the interior of flues or chimneys that are not readily accessible.
  8. Inspect fire screens or doors, seals or gaskets, mantles and surround, make up air devices or heat distribution assist systems.

Styles & Materials
HEAT TYPE:
FORCED DRAFT
ENERGY SOURCE:
GAS
NUMBER OF HEAT SYSTEMS (excluding wood):
ONE
HEAT SYSTEM BRAND:
RHEEM
DUCTWORK:
INSULATED
FILTER TYPE:
DISPOSABLE
FILTER SIZE:
16x20
TYPES OF FIREPLACES:
GAS/LP LOG STARTER
INSERT
OPERABLE FIREPLACES:
ONE
NUMBER OF WOODSTOVES:
NONE
FURNACE BTU/HR.:
75000
APPROXIMATE AGE:
2004

 INNINPCRR
6.0 HEATING EQUIPMENTX    
6.1 HEATING EQUIPMENT LOCATIONX    
6.2 NORMAL OPERATING CONTROLSX    
6.3 AUTOMATIC SAFETY CONTROLSX    
6.4 CHIMNEYS, FLUES AND VENTSX   X
6.5 HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)X    
6.6 GAS/LP FIRELOGS AND FIREPLACESX    
6.7 PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOMX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
6.1 The furnace is located in the attic.
6.4 Double wall "B" vent/furnace and water heater flues require a minimum of 1" air gap between the flue and combustible materials.  Remove flammable materials or make repairs as necessary to ensure that a 1" minimum space is maintained.  See photos for location(s) and/or example(s)

Recommend having a licensed HVAC technician make appropriate replacements and or repairs as necessary.



6.4 Picture 1

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report, please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email at Info@yourhomeanalyst.com.




CENTRAL AIR CONDITIONING

Styles & Materials
NUMBER OF A/C UNITS:
ONE
COOLING EQUIPMENT TYPE:
AIR CONDITIONER UNIT
COOLING EQUIPMENT ENERGY SOURCE:
ELECTRICITY
CENTRAL AIR MANUFACTURER:
RHEEM
COOLING EQUIPMENT CAPACITY IN TONS:
2.5
AGE OF COMPRESSOR (S):
2004

 INNINPCRR
7.0 COOLING EQUIPMENT LOCATIONX    
7.1 COOLING AND AIR HANDLER EQUIPMENTX   X
7.2 NORMAL OPERATING CONTROLSX    
7.3 DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)X    
7.4 PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOMX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
7.0 AC units are located on the rear of the house.
7.1 Ambient air test was performed by measuring the temperature of the supply air and the temperature of the return air of air conditioner to determine if the difference in temperatures is between 14 degrees and 22 degrees which indicates unit is cooling as intended. The supply air temperature on this system read 65 degrees, and the return air temperature was 74 degrees.

This indicates that the system is not cooling properly and a licensed Heating and Air contractor should inspect for cause or problem and make necessary repairs..

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email at info@yourhomeanalyst.com.




INTERIORS

GAHI Limitations for General Interior

The Inspector is not required to:

  1. Move furniture or owners possessions.
  2. Enter rooms where pets are loose.

Styles & Materials
CEILING MATERIALS:
SHEETROCK
WALL MATERIAL:
SHEETROCK
FLOOR COVERING(S):
CARPET
VINYL
WOOD
INTERIOR DOORS:
MASONITE
RAISED PANEL
CABINETRY:
WOOD
COUNTERTOP:
LAMINATE
REFRIGERATOR OPENING WIDTH:
36 INCHES
REFRIGERATOR OPENING HEIGHT:
68 INCHES

 INNINPCRR
8.0 CEILINGSX    
8.1 WALLSX    
8.2 FLOORSX   X
8.3 DOORS (REPRESENTATIVE NUMBER)X    
8.4 WINDOWS (REPRESENTATIVE NUMBER)X    
8.5 STEPS, STAIRWAYS, BALCONIES AND RAILINGSX    
8.6 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS AND DRAWERSX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
8.2 Vinyl shows wet stains indicating moisture or intrusion did or still may occur at master bath and laundry room.  See plumbing section for master bath floor stain.  Unable to determine source of stain in laundry room.  Have sellers identify source/reason for laundry room floor stain.

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report, please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email at info@yourhomeanalyst.com.




INSULATION AND VENTILATION

GAHI Limitations for Insulation and Ventilation

The Inspector is not required to:

  1. Evaluate ventilation adequacy by any means other than visual.
  2. Evaluate the efficiency of insulation.

Styles & Materials
R- VALUE:
R-30 OR BETTER
ATTIC INSULATION:
BLOWN
BATT
FIBERGLASS
EXHAUST FAN TYPES:
FAN ONLY
DRYER POWER SOURCE:
22O ELECTRIC
GAS CONNECTION
BOTH (YOUR CHOICE)
DRYER VENT:
METAL
ATTIC VENTILATION:
GABLE VENTS
SOFFIT VENTS
Thermostatically controlled fan

 INNINPCRR
9.0 INSULATION AND VAPOR RETARDERS (in unfinished spaces)X    
9.1 VENTILATION OF ATTIC AND FOUNDATION AREASX    
9.2 VENTING SYSTEMS (Kitchens, baths and laundry)X    
9.3 VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC)X   X
9.4 INSULATION SHIELDSX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:
9.3 Thermostatically controlled "vent fan" in attic was not accessible due to height of fan or due to low ambient temperature the fan was not running.  We did not inspect this unit.  Recommend verifying operation when the temperature in the attic is above 120 degrees.

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report please, contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email at info@yourhomeanalyst.com.




BUILT-IN KITCHEN APPLIANCES

GAHI Limitations for Kitchen and Appliances

The Inspector is not required to:

  1. Check calibration of temperature or determine that the oven-heated temperature corresponds to the control setting.
  2. Determine the efficiency of any equipment.
  3. Determine the remaining life of any equipment.
  4. Test or operate any equipment other than the ones outlined below.
  5. Test or inspect timer and/or other accessory type controls
  6. Inspector is not required to check microwave ovens for radiation leaks.
  7. Inspector is not required to operate or inspect trash compactors.
  8. Inspector is not required to inspect refrigerators.

Styles & Materials
DISHWASHER:
HOTPOINT
DISPOSER:
GENERAL ELECTRIC
EXHAUST/RANGE HOOD:
HOTPOINT
RANGE/OVEN:
HOTPOINT
BUILT-IN MICROWAVE:
HOTPOINT
TRASH COMPACTORS:
NONE

 INNINPCRR
10.0 DISHWASHERX    
10.1 RANGES/OVENS/COOKTOPSX    
10.2 RANGE HOODX    
10.3 TRASH COMPACTOR  X  
10.4 FOOD WASTE DISPOSERX    
10.5 BUILT IN MICROWAVE COOKING EQUIPMENTX    
10.6 REFRIGERATOR X   
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace

Please see the entire report for complete information.  If you should have any questions regarding the content or meaning of this report, please contact Home Analyst, Inc. by calling 404-978-2266 or you may reach us via email at info@yourhomeanalyst.com.




COMPLIMENTARY PHOTO VIEWS

 
 INNINPCRR
11.0 ATTIC VIEWX    
11.1 BREAKFAST ROOMX    
11.2 DEN VIEWX    
11.3 DINING ROOM VIEWX    
11.4 GARAGEX    
11.5 HALL BATH VIEWX    
11.6 KITCHEN VIEWX    
11.7 LIVING ROOM VIEWX    
11.8 MASTER BEDROOM VIEWX    
11.9 MASTER BATH VIEWX    
11.10 UPSTAIRS BATHX    
IN=Inspected, NI=Not Inspected, NP=Not Present, C=Code Requirement, RR=Repair or Replace
Comments:

11.0 View of Attic

11.0 Picture 1

11.0 Picture 2
11.1 Breakfast Room View

11.1 Picture 1
11.2 Den View

11.2 Picture 1
11.3 Dining Room View

11.3 Picture 1
11.4 View of Garage.

11.4 Picture 1
11.6 Kitchen view

11.6 Picture 1
11.7 Living Room View

11.7 Picture 1
11.8 Master Bedroom View

11.8 Picture 1
11.9 Master Bath View

11.9 Picture 1
11.10 Upstairs bath view

11.10 Picture 1

Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To Home Analyst, Inc.



Summary of Inspection Report


Home Analyst, Inc.

P.O. Box 670774
Marietta, GA 30066
404-978-2266
Bruce@yourhomeanalyst.com

Customer
Jane Homebuyer

Property Address
123 Shady Lane
Powder Springs, GA 30127

The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or appear to warrant further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

STRUCTURAL COMPONENTS
1.5 ATTIC AND ROOF STRUCTURE
 Inspected, Repair or Replace
 
Roof rafters bracing is inadequate and the rafters are sagging.  Lateral bracing (purlins) and purling braces are not properly installed. The purlins should be continuous and the braces must be placed four feet on center. 

For details and/or examples see photo(s):


EXTERIOR
2.1 DOORS (Exterior)
 Inspected, Repair or Replace
 
The wood door frame to metal threshold joint is not adequately caulked.  Failure to adequately seal this area may lead to rotting of the wood door frame.  This is especially important where the door and threshold will be exposed to the elements.  It is recommend that all of the factory glue squeeze out be removed, clean all surfaces of dirt and loose paint, prime area if necessary and seal with a high quality paintable sealant.
2.2 WINDOWS
 Inspected, Code Requirement, Repair or Replace
 
Thermal windows have lost their seal and have begun to cloud.  Repair or replace windows with damaged seals.

For details and/or examples, see photo(s):

2.7 VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building and it's systems)
 Inspected, Repair or Replace
 
Grade is too high. Dirt is in contact with the siding and/or trim of the house.  This can lead to water damage, rot and insect damage.  Ideally, the grade should be 6" below the bottom of the siding.  This makes it easy to inspect the foundation for insect activity and helps to prevent termites and water-related damage.  It is recommended that the dirt be removed and that final grading directs water drainage away from the house.

ROOFING
3.0 ROOF COVERINGS
 Inspected, Repair or Replace
 
Nail pops or other debris under shingle(s). Recommend having a qualified roofer make the appropriate repairs.

For examples see photos:


PLUMBING SYSTEM
4.0 EXTERIOR PLUMBING SYSTEMS
 Inspected, Repair or Replace
 
Hose bib is not properly anchored to the house siding. Recommend having a qualified plumber make the appropriate repairs and or replacements.  Near garage door.
4.1 INTERIOR WATER PRESSURE (record pressure)
 Inspected, Repair or Replace
 
Water pressure should be between 40 psi and 80 psi and when tested was found to be at 95 psi. The water pressure is too high.

Excessive pressure can cause damage to fixtures and fittings.  Have a qualified plumber adjust and or repair the pressure reducing valve as necessary to maintain house pressure between 40 and 80 psi.

4.2 SHOWER / TUB SURROUNDS AND ENCLOSURES
 Inspected, Repair or Replace
 
Active leak at shower resulting in stain.  Water was seen leaking up between edge of vinyl and tile in area circled in photo.  Have a qualified repair company make appropriate repairs to damaged areas to prevent further leaks.

ELECTRICAL SYSTEMS
5.3 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
 Inspected, Repair or Replace
 
Door bell does not operate.

HEATING
6.4 CHIMNEYS, FLUES AND VENTS
 Inspected, Repair or Replace
 
Double wall "B" vent/furnace and water heater flues require a minimum of 1" air gap between the flue and combustible materials.  Remove flammable materials or make repairs as necessary to ensure that a 1" minimum space is maintained.  See photos for location(s) and/or example(s)

Recommend having a licensed HVAC technician make appropriate replacements and or repairs as necessary.


CENTRAL AIR CONDITIONING
7.1 COOLING AND AIR HANDLER EQUIPMENT
 Inspected, Repair or Replace
 
Ambient air test was performed by measuring the temperature of the supply air and the temperature of the return air of air conditioner to determine if the difference in temperatures is between 14 degrees and 22 degrees which indicates unit is cooling as intended. The supply air temperature on this system read 65 degrees, and the return air temperature was 74 degrees.

This indicates that the system is not cooling properly and a licensed Heating and Air contractor should inspect for cause or problem and make necessary repairs..


INTERIORS
8.2 FLOORS
 Inspected, Repair or Replace
 
Vinyl shows wet stains indicating moisture or intrusion did or still may occur at master bath and laundry room.  See plumbing section for master bath floor stain.  Unable to determine source of stain in laundry room.  Have sellers identify source/reason for laundry room floor stain.

INSULATION AND VENTILATION
9.3 VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC)
 Inspected, Repair or Replace
 
Thermostatically controlled "vent fan" in attic was not accessible due to height of fan or due to low ambient temperature the fan was not running.  We did not inspect this unit.  Recommend verifying operation when the temperature in the attic is above 120 degrees.


Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To Home Analyst, Inc.




Addendum: Useful Information for the Buyer


Home Analyst, Inc.

P.O. Box 670774
Marietta, GA 30066
404-978-2266
Bruce@yourhomeanalyst.com

Customer
Jane Homebuyer

Property Address
123 Shady Lane
Powder Springs, GA 30127

Standards of practiced for the American Society of Home Inspectors (ASHI) and the Georgia Association of Home Inspectors (GAHI) require that only significant defects be listed on home inspections.  Cosmetic, normal wear-and-tear, and other items are not to be listed in an inspection report.  As an added-value service, Home Analyst, Inc. has included this addendum in addition to the Summary.  Items listed in this addendum are for informational purposes only and should not be considered as part of the official inspection as these items would otherwise not be included in this inspection report.  Without this section, this information would be lost and not available to our clients.  You have made a considerable investment in a home inspection; Home Analyst,wants to ensure you receive the most comprehensive information possible from this investment.

EXTERIOR
2.0 WALL CLADDING, FLASHING AND TRIM
 Inspected
 
Louisiana Pacific siding has  been the subject of a class action lawsuit.  Please view the following website for more complete information about the status of the suit and issues concerning this type of siding.  http://www.lpsidingclaims.com/ 

ROOFING
3.1 FLASHINGS
 Inspected
 
The roof is improperly flashed.  Single piece flashing and a modified flashing has been installed. Step-flashing should have been installed at the time the roof was installed.  Due to the age of the roof and since there was no visible evidence of roof leaks, installing step-flashing at this time is not recommended.  When the roof is replaced in the future, ensure that the roofer properly installs step-flashing as required by code when over 50% of the roofing is replaced.  The following code has been provided for the buyer's convenience.

 

CODE ICC R905.2.8.4 Sidewall flashing. Flashing against a vertical sidewall shall be by the step-flashing method.

For details and/or examples, see photo(s):

Website: Roof Flashing http://www.ibacos.com/pubs/RoofFlashingGuidelines.pdf
3.3 ROOFING DRAINAGE SYSTEMS, GUTTERS& DOWNSPOUTS
 Inspected
 
Gutter is rusted and deteriorated in various areas throughout. Should be replaced when the roof is replaced or when leaks develop.

PLUMBING SYSTEM
4.3 INTERIOR WATER SUPPLY, DISTRIBUTION SYSTEMS AND FIXTURES
 Inspected
 
Polybutylene plastic plumbing supply lines (PB) are installed in the subject house. Polybutylene has been used in this area for many years, but has had a higher than normal failure rate, and is no longer being widely used. Copper and brass fittings used in later years have apparently reduced the failure rate. This subject house has copper fittings. For further details, contact the Consumer Plumbing Recovery center at 1-800-392-7591 or the web at http://www.pbpipe.com.
4.8 MAIN WATER SHUT-OFF DEVICE (Describe location)
 Inspected
 
See photo 1 for location of main water valve. The main shut-off is the white lever beside water heater.


Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2004 : Licensed To Home Analyst, Inc.




Home Analyst, Inc.

Bruce Rickey
P.O. Box 670774
Marietta, GA 30066
404-978-2266
Bruce@yourhomeanalyst.com



  INVOICE

Home Analyst, Inc.
P.O. Box 670774
Marietta, GA 30066
404-978-2266
Bruce@yourhomeanalyst.com
Inspected By:  Bruce Rickey
Inspection Date: 7/5/2006
Report ID: 06070501-homebuyer

Customer Info: Inspection Property:
Jane Homebuyer
2550 Old Place
D-19
Atlanta GA 30000


Customer's Real Estate Professional:
John H. Onest
Best Homes  
123 Shady Lane
Powder Springs, GA 30127
 

Inspection Fee:
Service Price Amount Sub-Total
Base Fee 3 bed room 2 bath 275.00 1 275.00
10-25 Years old 25.00 1 25.00

Tax $0.00
Total Price $300.00

Payment Method:Check
Payment Status:Paid At Time Of Inspection
Note:Check Number 1296




Client's Name(s): Jane Homebuyer
Client's Phone Numbers: